Babel Buster BB2-6010 Modbus to SNMP, Modbus RTU to TCP Gateway
Babel Buster BB2-6010 is a self contained server that will autonomously poll multiple serial devices and store the data for later forwarding via Modbus TCP, and vice versa. BB2-6010 includes Modbus RTU master and slave, Modbus TCP client and server, SNMP client and server (agent), v2c traps.

Babel Buster BB2-6010 Modbus to SNMP, Modbus RTU to TCP Gateway

Your Price: $529.00
Retail Price:$661.00
Your Savings:$132.00(20%)
Part Number:BB2-6010

Choose Options

Extended Memory Option help
Serial Port help

Babel Buster BB2-6010 is a Modbus to Modbus and a Modbus to SNMP Gateway. The BB2-6010 is more than a protocol translator. It is a self contained server that collects and distributes data according to the rules you create. The most common use of the BB2-6010 is to map Modbus RTU and/or Modbus TCP devices to SNMP. The SNMP manager can use SNMP Get to retrieve contents of any mapped Modbus register. In addition, the BB2-6010 uses threshold rule templates to continuously monitor Modbus data and generate SNMP Traps upon sensing of “alarm” conditions.

Babel Buster BB2-6010 is an SNMP Agent (server), but also includes an SNMP Client. This means the BB2-6010 can query other SNMP devices and make their data available to Modbus or rule processing to generate traps not originally provided by the other SNMP equipment.

BB2-6010

The primary applications for Babel Buster BB2-6010 are serial to Ethernet conversion for Modbus devices, and SNMP access to serial or Ethernet Modbus devices. As a Modbus to Modbus gateway, the BB2-6010 will map multiple RTU devices to a single Modbus TCP server map. It can also map multiple Modbus TCP devices to a single RTU slave map. The BB2-6010 can also do Modbus TCP to Modbus TCP register re-mapping to retrofit equipment to a legacy Modbus register map. The Modbus RTU port can be configured as master or slave. The Modbus TCP port can operate as both client and server (master and slave) concurrently.

• Modbus RTU RS-485 Master or Slave
• Modbus TCP Client and Server
• Modbus TCP over Ethernet 10/100BaseT
• SNMP get/set access to all data points
• SNMP trap generation, user programmable criteria
• 1000 16-bit registers (300 useable for SNMP)
• 500 32-bit floating point registers (100 useable for SNMP)
• Supports Modbus “coils”, input registers, holding registers
• Single/double, signed/unsigned, and IEEE 754
• Modbus register mapping configured via web interface
• Modbus register scaling (x10, x100, x0.1, x0.01, etc.)
• Modbus (master) polling interval configurable per point
• User defined “virtual device” register map
• Supports user HTML “wrapper” 
• Configure via web pages
• Flash file system with XML configuration files
• Online help
• Password protection for web log-on and ftp
• Field upgradeable firmware upload via ftp
• DHCP or static IP address
• Hardened EIA-485 transceiver for Modbus RTU
• Optional RS-232 transceiver (in place of RS-485)
• Powered by 10-30VDC or 12-24VAC 50/60 Hz
• Power Consumption: 0.1A @ 24VDC
• DIN rail mounting, 100mm H x 70mm W x 60mm D
• Pluggable screw terminal block for power & RTU network
• Operating temperature -40°C to +85°C
• Humidity 5% to 90%
• FCC Class A, CE Mark
• Listed* to UL 916 and (Canadian) C22.2 No. 205-M1983
   * BB2-6010 is UL Listed with RS-485, listing of new RS-232 option is pending