Babel Buster BB2-7010 BACnet IP to Modbus, SNMP Gateway
Babel Buster BB2-7010 BACnet IP to Modbus Gateway is a BACnet IP client & server with a Modbus RTU master and slave, plus Modbus TCP client and server. Additional variants add SNMP client and server, and WiFi sensor support.

Babel Buster BB2-7010 BACnet IP to Modbus, SNMP Gateway

Your Price: $529.00
Retail Price:$661.00
Your Savings:$132.00(20%)
Part Number:BB2-7010

Choose Options

Device Firmware Version
Extended Memory Option help
Serial Port help

Babel Buster BB2-7010-01 contains three different clients and three different servers. The 7010 includes BACnet/IP client and server, Modbus TCP client and server (master and slave), and Modbus RTU master and slave.


The BACnet IP client allows BACnet IP devices to be accessible from Modbus TCP or RTU. You configure the device instance, object type and instance, and poll interval for reading or writing BACnet objects. The object data is stored in the IP/XM server for subsequent retrieval by any supported remote client (or master).

A large number of BACnet objects gives you flexibility in mapping Modbus registers to any combination of BACnet objects. Packed Modbus registers may be parsed to multiple BACnet objects when reading. Multiple BACnet objects may be packed into a single Modbus register when writing. All standard Modbus register types are supported.

BB2-7010-02 adds an SNMP client and server. The SNMP client allows SNMP devices to be accessible from BACnet IP or Modbus. You configure the SNMP agent's IP address, the OID of the MIB variable you wish to poll, and set a polling interval. The object data is stored in the 7010 server for subsequent retrieval by any supported remote client.

BB2-7010-06 includes a WiFi sensor server which collects data via a WiFi access point from PointSix or AirTest WiFi sensors. The BB2-7010-06 receives UDP data packets from sensors via a generic off-the-shelf WiFi access point, parses the data packet, and places the sensor data in one or more BACnet objects. The sensor data objects may be accessed via BACnet IP, Modbus TCP, Modbus RTU, or SNMP using the BB2-7010-07.

BB2-7010-07 is an extension of the BB2-7010 family that adds support for Veris Industries WiFi sensors. BB2-7010-07 receives UDP or TCP data packets from sensors via a generic off-the-shelf WiFi access point, parses the data packet, and places the sensor data in one or more BACnet objects. The sensor data objects may be accessed via BACnet IP, Modbus TCP, Modbus RTU, or SNMP using the BB2-7010-07.

Babel Buster BB2-7010-08 is an extension of the BB2-7010 family that adds support for Functional Devices WiFi RIB relays/sensors. The BB2-7010-08 queries the RIB via a generic off-the-shelf WiFi access point, parses the data packet, and places the sensor data in one or more BACnet objects. The sensor data objects may be accessed via BACnet IP, Modbus TCP, Modbus RTU, or SNMP using the BB2-7010-08. The relay in the RIB can be controlled by a BACnet Binary Output object in the gateway. The gateway also provides binding between a discrete input on one RIB to the relay output on a different RIB if configured by the user

Value objects will poll their assigned Modbus register at the interval you specify. The content of the Modbus register will be given as the Present Value of the BACnet object when read. The Modbus register is written each time the BACnet Value object is written. The Value object corresponds well with the Modbus Holding register.

Input objects will poll their assigned Modbus register at the interval you specify, and provide the Modbus data as the Present Value when read. Commandable Output objects are used to write Modbus registers, and will update the Modbus device each time BACnet is updated.

The same polling schemes that apply to Modbus also apply to remote BACnet IP slaves polled by the 7010's BACnet IP client, and apply to SNMP or WiFi sensor polling as applicable.

• Universal, fully configurable
• No extra software or drivers to buy

• Read/Write any standard Modbus register via BACnet 
• Read/Write any standard BACnet object via Modbus
• Bidirectional communication between BACnet and Modbus
• Supports Modbus “coils”, input registers, holding registers
• Single or double Modbus registers
• Signed, unsigned, IEEE 754
• Modbus register mapping configured via web interface
• Modbus registers may be scaled (x10, x0.1, etc.)
• Modbus (master) polling interval configurable per point
• Commandable BACnet objects implement priority array
• Hardened EIA-485 transceiver for Modbus RTU
• Optional RS-232 transceiver (in place of RS-485)
• 10/100BaseT Ethernet for BACnet IP and Modbus TCP
• Powered by 10-30VDC or 12-24VAC 50/60 Hz
• Power Consumption: 0.1A @ 24VDC
• DIN rail mounting, 100mm H x 70mm W x 60mm D
• Pluggable screw terminal block for power & RTU network
• Operating temperature -40°C to +85°C
• Humidity 5% to 90%
• FCC Class A, CE Mark
• Listed* to UL 916 and (Canadian) C22.2 No. 205-M1983
   * BB2-7010 is UL Listed with RS-485, listing of new RS-232 option is pending